Florida Bids > Bid Detail

Mobile Generator 2 Mega Watt; 1050 Gal double wall fuel tank each gen set 80 Gal DEF tank Exterior fuel & DEF supply connections, ABS, Air Ride, Two Axle, 48- ISO container chassis

Agency: VETERANS AFFAIRS, DEPARTMENT OF
Level of Government: Federal
Category:
  • 54 - Prefabricated Structures and Scaffolding
  • 61 - Electric Wire, and Power and Distribution Equipment
  • 81 - Containers, Packaging, and Packing Supplies
Opps ID: NBD00159738918906637
Posted Date: May 17, 2023
Due Date: Jun 4, 2023
Solicitation No: 23-AP-4217-GEN
Source: https://sam.gov/opp/c8b189970d...
Follow
Mobile Generator 2 Mega Watt; 1050 Gal double wall fuel tank each gen set 80 Gal DEF tank Exterior fuel & DEF supply connections, ABS, Air Ride, Two Axle, 48- ISO container chassis
Active
Contract Opportunity
Notice ID
23-AP-4217-GEN
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
248-NETWORK CONTRACT OFFICE 8 (36C248)
Looking for contract opportunity help?

Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
  • Original Published Date: May 17, 2023 04:09 pm EDT
  • Original Response Date: Jun 04, 2023 04:00 pm EDT
  • Inactive Policy: 15 days after response date
  • Original Inactive Date:
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code:
  • NAICS Code:
    • 333618 - Other Engine Equipment Manufacturing
  • Place of Performance:
    Daytona Beach , FL 32117
    USA
Description

2 Mega Watts Mobile Generator (Brand Name or Equal)





ENGINE PACKAGE DESCRIPTION



Clean Emissions Module



(CEM) w/integrated Diesel Oxidation Catalyst(DOC),



Selective Catalytic Reduction (SCR), & Ammonia Oxidation Catalyst



(AMOX) AND IS EPA TIER 4F EMISSIONS CERTIFIED.



CIRCUIT BREAKERS





3200A electrically operated, fixed type, 3 pole, insulated case circui



Basler UMR



Solid state trip unit for overload (time overcurrent) and fault



(instantaneous) overcurrent protection



Includes DC shunt trip coil activated on any monitored engine or



electrical fault



Undervoltage release





COOLING SYSTEM





Minimum 43 Deg C (117 Deg F) 500 M (1640 ft.)



Vertically mounted radiator with vertical discharge



Variable Speed Fan and belt guards



Coolant drain line with internal valve



Coolant sight gauge, level switch with shutdown



Extended Life Coolant (50/50)



Jacket water heater with isolation valves



DISTRIBUTION PANEL



Busbar connections



Externally-accessible, Vibration Isolated, 3200A Frame, 100 Ka, IC,



3-pole electrically operated breaker with lock out tag out provision.



Dedicated power cubicle in container wall.



Dedicated cable tie down points to secure load cables and relieve



cable stress.



Hinged load cover door which must be closed for main breaker operation



Neutral earth link



Shunt Trip



Remote start terminals



Lockable door



Side hinged Lockable doors with rust resistant



pinned hinges.



Bus bar connection with easy access for connections



through bottom of unit, even when on the ground.



Separate control and load sections.



Shore Power Circuits for



240V 30A Generator heater, Fuel Transferer pump &



Remote DEF tank heater



240V 50A Air Compressor Heater, Jacket Water Heater,



DEF Tank Heater



120V Battery Charger



Paralleling interface connections



Remote start terminals



Current transformers, hard mounted.



ENCLOSURES



48' ISO High Cube container



Sound attenuated to 82.7 dB(A) at 7 meters at 75% Prime



Spill containment - (110% onboard engine fluids)



Five Cat Key lockable (or padlockable) personnel doors with



hold open rods



Package mounted bus bar connections



Vertical air discharge



Removable six step stairway with handrail



Stairways (3) and handrails (3) packaged in radiator compartment



(8) - 24VDC Interior Lights with 60 minute wall mounted timer



(1) - 120VAC wall mounted duplex GFI receptacle(connected to shore power and generator power)



Sound attenuated intake



EXHAUST SYSTEM



Integral with flexible connector



FUEL SYSTEM



1050 Gallon double wall fuel tank for each generator set



80 Gallon DEF tank



Exterior fuel & DEF supply connections



Dual Racor Filters with water separator and vacuum gauge



Fuel Filter Spill Containment with drain



Radiator mounted fuel cooler



Motorized fuel priming pump



Digital fuel level gauge



UL142 & UN31A Approved



GENERATORS AND GENERATOR ATTACHMENTS



3 Phase brushless, 6 lead, Permanent Magnet Excited



Class H insulation, Class F temperature rise at 40DEC



ambient (105C prime)



Anti-condensation space heaters



Includes Integrated voltage regulator (IVR) with



KVAR/PF modes, RFI suppression, min/max exciter limiter



and exciter diode monitor.



VOLTAGE REGULATION



Integrated voltage regulator,



microprocessor based.



Manual raise/lower voltage adjust capability



RFI suppression, exciter limiter and exciter diode monitoring



STARTING/CHARGING SYSTEM



60 amp charging alternator



24 Volt Electric Starting Motors



Two Batteries (24V-Maintenance Free, 1400 CCA)



Battery rack w/cables mounted in diamond plate cover



Battery disconnect switch



50 Amp battery charger (wall mounted)



Solar power battery maintainer with isolator



CONTROL SYSTEM



Generator mounted EMCP 4.4 provides power metering, protective



relaying and engine and generator control, monitoring and paralleling



NEMA 12, IP44 Dust Proof Enclosure



UL508A Listed



Integration with the IVR provides enhanced system monitoring.



Ability to view and reset diagnostics of all controls networked on



primary CAN datalink eliminates need for separate service tools



for troubleshooting.



True RMS AC metering, 3 phase



Emergency Stop Button



Panel illuminating lights



Display navigation keys including 2 shortcut keys for engine



and generator parameters



Fuel level monitoring and control



Rated/Idle Speed Switch



Multiple stored setpoint group selection via switched input



Controls:



Run/Auto/Stop



Engine cool-down timer



Engine cycle crank



Voltage & Speed Adjustments



Panel illuminating lights



Alarm acknowledge



Alarm reset



Digital indication for:



RPM



Operating hour



Oil pressure (psi, kPa or bar)



Coolant temperature (OEC or OEF)



DC Volts



Oil Temperature (OEC or OEF)



L-L Volts, L-N Volts, Phase amps



Average volts, Amps, Frequency



ekW, kVa, kVAR, kW-hr, % kW,



Power Factor (Average, Phase)



kW-hr, kVA-hr (total)



Warning/Shutdown with indicating lights for:



Low oil pressure



High coolant temperature



Overspeed



Emergency stop



Failure to start (overcrank)



Low coolant level



High oil temperature



Programmable Protective Relaying Functions



Phase over/under Voltage



Under and Over Frequency



Reverse Power



Current Balance



Over Current (Phase and Total)



Loss of Excitation



Bus Phase Sequence



Modes of operation



Single Unit Island Mode



Multiple Unit Island Mode - Automatic and Manual Paralleling



Single Unit Utility Parallel Mode - Automatic and Manual Paralleling



Paralleling Functions



Load sharing



Load sense/Load demand



Load Shed/Load add



Dead bus arbitration



Synchronizing



TRAILER



Anti-lock Brake System



Air Ride



Two Axle, 48- ISO container chassis


Attachments/Links
Contact Information
Contracting Office Address
  • 8875 HIDDEN RIVER PARKWAY
  • TAMPA , FL 33637
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • May 17, 2023 04:09 pm EDTSources Sought (Original)

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.

Start Free Trial Today >